| # Helpful information: | |
| # https://github.com/Excodibur/ioBroker.schwoerer-ventcube/blob/master/src/lib/schwoerer/parameters.ts | |
| # https://github.com/fgoettel/wgt/blob/main/wgt/lueftungsanlage.py | |
| # https://knx-user-forum.de/forum/öffentlicher-bereich/knx-eib-forum/diy-do-it-yourself/1822296-modbus-schwörer-heizung?p=1906252#post1906252 | |
| ################## | |
| # MODBUS SENSORS # | |
| ################## | |
| modbus: | |
| - name: BIC_VentCube | |
| delay: 2 | |
| timeout: 5 | |
| message_wait_milliseconds: 50 | |
| type: tcp | |
| host: !secret wgt_ip | |
| port: 502 | |
| sensors: | |
| - name: VentCube Betriebsart | |
| slave: 1 | |
| unique_id: ventcube_betriebsart | |
| address: 100 | |
| # Translated with template sensor | |
| # Translated with input_select Automation | |
| - name: VentCube Manuelle Luftstufe | |
| slave: 1 | |
| unique_id: ventcube_manuelle_luftstufe | |
| address: 101 | |
| # Translated with input_select Automation | |
| - name: VentCube Aktuelle Luftstufe | |
| slave: 1 | |
| unique_id: ventcube_aktuelle_luftstufe | |
| address: 102 | |
| - name: VentCube Status Stoßlüftung | |
| slave: 1 | |
| unique_id: ventcube_status_stosslueftung | |
| address: 111 | |
| # Translated with template sensor | |
| - name: VentCube Restlaufzeit Stoßlüftung | |
| slave: 1 | |
| unique_id: ventcube_restlaufzeit_stosslueftung | |
| address: 112 | |
| unit_of_measurement: min | |
| device_class: duration | |
| min_value: 0 | |
| max_value: 60 | |
| - name: VentCube Status Wärmepumpe | |
| slave: 1 | |
| unique_id: ventcube_status_waermepumpe | |
| address: 114 | |
| # Translated with template sensor | |
| - name: VentCube Status Nachheizregister | |
| slave: 1 | |
| unique_id: ventcube_status_nachheizregister | |
| address: 116 | |
| # Translated with template sensor | |
| - name: VentCube Status Gebläse Zuluft | |
| slave: 1 | |
| unique_id: ventcube_status_geblaese_zuluft | |
| address: 117 | |
| # Translated with template sensor | |
| - name: VentCube Status Gebläse Abluft | |
| slave: 1 | |
| unique_id: ventcube_status_geblaese_abluft | |
| address: 118 | |
| # Translated with template sensor | |
| - name: VentCube Zustand Bypass | |
| slave: 1 | |
| unique_id: ventcube_bypass_zustand | |
| address: 123 | |
| # Translated with template sensor | |
| - name: VentCube Zustand Außenklappe | |
| slave: 1 | |
| unique_id: ventcube_zustand_aussenklappe | |
| address: 131 | |
| # Translated with template sensor | |
| - name: VentCube Status Vorheizregister | |
| slave: 1 | |
| unique_id: ventcube_status_vorheizregister | |
| address: 133 | |
| # Translated with template sensor | |
| - name: VentCube aktuelle Luftleistung Zuluft | |
| slave: 1 | |
| unique_id: ventcube_aktuelle_luftleistung_zuluft | |
| address: 142 | |
| state_class: measurement | |
| unit_of_measurement: "%" | |
| min_value: 0 | |
| max_value: 100 | |
| scale: 1 | |
| precision: 0 | |
| - name: VentCube aktuelle Luftleistung Abluft | |
| unique_id: ventcube_aktuelle_luftleistung_abluft | |
| slave: 1 | |
| address: 143 | |
| state_class: measurement | |
| unit_of_measurement: "%" | |
| min_value: 0 | |
| max_value: 100 | |
| scale: 1 | |
| precision: 0 | |
| - name: VentCube aktuelle Drehzahl Zuluft | |
| unique_id: ventcube_aktuelle_drehzahl_zuluft | |
| slave: 1 | |
| address: 144 | |
| state_class: measurement | |
| unit_of_measurement: "rpm" | |
| min_value: 0 | |
| max_value: 10000 | |
| precision: 0 | |
| - name: VentCube aktuelle Drehzahl Abluft | |
| unique_id: ventcube_aktuelle_drehzahl_abluft | |
| slave: 1 | |
| address: 145 | |
| state_class: measurement | |
| unit_of_measurement: "rpm" | |
| min_value: 0 | |
| max_value: 10000 | |
| precision: 0 | |
| - name: VentCube T2 Temperatur nach Vorheizregister | |
| slave: 1 | |
| unique_id: ventcube_t2_temperatur_nach_vorheizregister | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 201 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T3 Temperatur vor Nacherwärmung | |
| slave: 1 | |
| unique_id: ventcube_t3_temperatur_vor_nacherwaermung | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 202 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T4 Temperatur nach Nacherwärmung | |
| slave: 1 | |
| unique_id: ventcube_t4_temperatur_nach_nacherwaermung | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 203 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T5 Temperatur Abluft | |
| slave: 1 | |
| unique_id: ventcube_t5_temperatur_abluft | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 204 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T6 Temperatur im Wärmetauscher | |
| slave: 1 | |
| unique_id: ventcube_t6_temperatur_im_waermetauscher | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 205 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T10 Temperatur Außen | |
| slave: 1 | |
| unique_id: ventcube_t10_temperatur_aussen | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 209 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube Heiz- Kühlfunktion | |
| slave: 1 | |
| unique_id: ventcube_heiz_kuehlfunktion | |
| address: 230 | |
| # Translated with template sensor | |
| # Translated with input_select Automation | |
| - name: VentCube Wärmepumpe Heizen | |
| slave: 1 | |
| unique_id: ventcube_wp_heizen | |
| address: 231 | |
| - name: VentCube Wärmepumpe Kühlen | |
| slave: 1 | |
| unique_id: ventcube_wp_kuehlen | |
| address: 232 | |
| - name: VentCube Druckwächter aktiv | |
| slave: 1 | |
| unique_id: ventcube_druckwachter_aktiv | |
| address: 242 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube EVU Sperre aktiv | |
| slave: 1 | |
| unique_id: ventcube_evu_sperre_aktiv | |
| address: 243 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Wartungstür offen | |
| slave: 1 | |
| unique_id: ventcube_wartungstur_offen | |
| address: 244 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Gerätefilter verschmutzt | |
| slave: 1 | |
| unique_id: ventcube_geratefilter_verschmutzt | |
| address: 245 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Vorgelagerter Filter verschmutzt | |
| slave: 1 | |
| unique_id: ventcube_vorgelagerter_filter_verschmutzt | |
| address: 246 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Zuluft zu kalt | |
| slave: 1 | |
| unique_id: ventcube_zuluft_zu_kalt | |
| address: 254 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Restlaufzeit Gerätefilter | |
| slave: 1 | |
| unique_id: ventcube_restlaufzeit_geratefilter | |
| address: 265 | |
| unit_of_measurement: d | |
| min_value: 0 | |
| max_value: 255 | |
| device_class: duration | |
| - name: VentCube Temperatur Wohnzimmer IST | |
| slave: 1 | |
| unique_id: ventcube_temperatur_wohnzimmer_ist | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 360 | |
| scale: 0.1 | |
| precision: 1 | |
| min_value: 0 | |
| max_value: 100 | |
| switches: | |
| - name: VentCube Freigabe WP auf Heizen | |
| slave: 1 | |
| address: 231 | |
| command_on: 0x1 # Freigabe | |
| command_off: 0x0 # Gesperrt | |
| write_type: holdings | |
| verify: | |
| input_type: holding | |
| state_on: 0x1 | |
| state_off: 0x0 | |
| delay: 5 | |
| unique_id: ventcube_set_waermepumpe_heizen | |
| - name: VentCube Freigabe WP auf Kühlen | |
| slave: 1 | |
| address: 232 | |
| command_on: 0x1 # Freigabe | |
| command_off: 0x0 # Gesperrt | |
| write_type: holdings | |
| verify: | |
| input_type: holding | |
| state_on: 0x1 | |
| state_off: 0x0 | |
| delay: 5 | |
| unique_id: ventcube_set_waermepumpe_kuehlen | |
| climates: | |
| - name: "VentCube Soll-Temperatur" | |
| unique_id: ventcube_soll_temperatur | |
| slave: 1 | |
| address: 400 | |
| max_temp: 30 | |
| min_temp: 10 | |
| offset: 0 | |
| precision: 0 | |
| scale: 0.1 | |
| target_temp_register: 400 | |
| target_temp_write_registers: true | |
| temp_step: 1 | |
| temperature_unit: °C | |
| - name: "VentCube Basis-Temperatur" | |
| unique_id: ventcube_basis_temperatur | |
| slave: 1 | |
| address: 420 | |
| max_temp: 30 | |
| min_temp: 18 | |
| offset: 0 | |
| precision: 0 | |
| scale: 0.1 | |
| target_temp_register: 420 | |
| target_temp_write_registers: true | |
| temp_step: 1 | |
| temperature_unit: °C | |
| ##################################################### | |
| # Select Options which require separate Automations # | |
| ##################################################### | |
| input_select: | |
| ventcube_manuelle_luftstufe: | |
| name: VentCube Manuelle Luftstufe | |
| options: | |
| - "0 - Aus" | |
| - "1 - Stufe 1" | |
| - "2 - Stufe 2" | |
| - "3 - Stufe 3" | |
| - "4 - Stufe 4" | |
| - "5 - Automatik" | |
| - "6 - Linearbetrieb" | |
| icon: mdi:fan | |
| ventcube_betriebsart: | |
| name: VentCube Betriebsart | |
| options: | |
| - "0 - Aus" | |
| - "1 - Handbetrieb" | |
| - "2 - Winterbetrieb" | |
| - "3 - Sommerbetrieb" | |
| - "4 - Sommer Abluft" | |
| icon: mdi:fan | |
| ventcube_heiz_kuehlfunktion: | |
| name: VentCube Heiz- Kühlfunktion | |
| options: | |
| - "0 - Aus" | |
| - "1 - Heizen" | |
| - "2 - Kühlen" | |
| - "3 - Auto T-Außen" | |
| - "4 - Auto Digitaler Eingang" | |
| icon: mdi:fan | |
| #################### | |
| # TEMPLATE SENSORS # | |
| #################### | |
| template: | |
| - sensor: | |
| - unique_id: ventcube_status_nachheizregister_text | |
| default_entity_id: sensor.ventcube_status_nachheizregister_text | |
| name: "VentCube Status Nachheizregister" | |
| state: >- | |
| {% set mapper = { | |
| '0': 'Inaktiv', | |
| '1': 'Aktiv' | |
| } %} | |
| {% set s = states('sensor.ventcube_status_nachheizregister') %} | |
| {{ mapper[s] if s in mapper else 'Unknown' }} | |
| - sensor: | |
| - unique_id: ventcube_betriebsart_text | |
| default_entity_id: sensor.ventcube_betriebsart_text | |
| name: "VentCube Betriebsart" | |
| state: >- | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '1': 'Handbetrieb', | |
| '2': 'Winterbetrieb', | |
| '3': 'Sommerbetrieb', | |
| '4': 'Sommer Abluft' | |
| } %} | |
| {% set s = states('sensor.ventcube_betriebsart') %} | |
| {{ mapper[s] if s in mapper else 'Unknown' }} | |
| - sensor: | |
| - unique_id: ventcube_bypass_zustand_text | |
| default_entity_id: sensor.ventcube_bypass_zustand_text | |
| name: "VentCube Zustand Bypass" | |
| state: >- | |
| {% set mapper = { | |
| '0': 'Geschlossen', | |
| '1': 'Offen (Kühlen)', | |
| '2': 'Offen (Heizen)' | |
| } %} | |
| {% set s = states('sensor.ventcube_bypass_zustand') %} | |
| {{ mapper[s] if s in mapper else 'Unknown' }} | |
| - sensor: | |
| - unique_id: ventcube_zustand_aussenklappe_text | |
| default_entity_id: sensor.ventcube_zustand_aussenklappe_text | |
| name: "VentCube Zustand Außenklappe" | |
| state: >- | |
| {% set mapper = { | |
| '0': 'Geschlossen', | |
| '1': 'Offen' | |
| } %} | |
| {% set s = states('sensor.ventcube_zustand_aussenklappe') %} | |
| {{ mapper[s] if s in mapper else 'Unknown' }} | |
| - sensor: | |
| - unique_id: ventcube_status_waermepumpe_text | |
| default_entity_id: sensor.ventcube_status_waermepumpe_text | |
| name: "VentCube Status Wärmepumpe" | |
| state: >- | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '5': 'WP Heizen', | |
| '49': 'WP Kühlen' | |
| } %} | |
| {% set s = states('sensor.ventcube_status_waermepumpe') %} | |
| {{ mapper[s] if s in mapper else 'Unknown' }} | |
| - sensor: | |
| - unique_id: ventcube_heiz_kuehlfunktion_text | |
| default_entity_id: sensor.ventcube_heiz_kuehlfunktion_text | |
| name: "VentCube Status Heiz- Kühlfunktion" | |
| state: >- | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '1': 'Heizen', | |
| '2': 'Kühlen', | |
| '3': 'Auto T-Außen', | |
| '4': 'Auto Digitaler Eingang' | |
| } %} | |
| {% set s = states('sensor.ventcube_heiz_kuehlfunktion') %} | |
| {{ mapper[s] if s in mapper else 'Unknown' }} | |
| - sensor: | |
| - unique_id: ventcube_status_vorheizregister_text | |
| default_entity_id: sensor.ventcube_status_vorheizregister_text | |
| name: "VentCube Status Vorheizregister" | |
| state: >- | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '1': 'VHR1 Aktiv', | |
| '2': 'VHR2 Aktiv', | |
| '3': 'VHR1+2 Aktiv' | |
| } %} | |
| {% set s = states('sensor.ventcube_status_vorheizregister') %} | |
| {{ mapper[s] if s in mapper else 'Unknown' }} | |
| - sensor: | |
| - unique_id: ventcube_status_geblaese_zuluft_text | |
| default_entity_id: sensor.ventcube_status_geblaese_zuluft_text | |
| name: "VentCube Status Gebläse Zuluft" | |
| state: >- | |
| {% set mapper = { | |
| '0': 'Deaktiviert', | |
| '1': 'Anlaufphase', | |
| '2': 'Aktiv', | |
| '5': 'Standby', | |
| '6': 'Fehler' | |
| } %} | |
| {% set s = states('sensor.ventcube_status_geblaese_zuluft') %} | |
| {{ mapper[s] if s in mapper else 'Unknown' }} | |
| - binary_sensor: | |
| - name: "VentCube Meldung Druckwächter Aktiv" | |
| unique_id: ventcube_meldung_druckwachter_aktiv | |
| default_entity_id: binary_sensor.ventcube_meldung_druckwachter_aktiv | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_druckwachter_aktiv.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung EVU Sperre aktiv" | |
| unique_id: ventcube_meldung_evu_sperre_aktiv | |
| default_entity_id: binary_sensor.ventcube_meldung_evu_sperre_aktiv | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_evu_sperre_aktiv.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Wartungstür offen" | |
| unique_id: ventcube_meldung_wartungstur_offen | |
| default_entity_id: binary_sensor.ventcube_meldung_wartungstur_offen | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_wartungstur_offen.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Gerätefilter verschmutzt" | |
| unique_id: ventcube_meldung_geratefilter_verschmutzt | |
| default_entity_id: binary_sensor.ventcube_meldung_geratefilter_verschmutzt | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_geratefilter_verschmutzt.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Vorgelagerter Filter verschmutzt" | |
| unique_id: ventcube_meldung_vorgelagerter_filter_verschmutzt | |
| default_entity_id: binary_sensor.ventcube_meldung_vorgelagerter_filter_verschmutzt | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'on', | |
| '1': 'off'} %} | |
| {% set state = states.sensor.ventcube_vorgelagerter_filter_verschmutzt.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Zuluft Zu Kalt" | |
| unique_id: ventcube_meldung_zuluft_zu_kalt | |
| default_entity_id: binary_sensor.ventcube_meldung_zuluft_zu_kalt | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_zuluft_zu_kalt.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
Hallo miteinander,
wir sind seid Januar auch stolzer Besitzer eines Schwörer Hauses.
Wir sind immer davon ausgegangen, dass wir mit unserem extra dazu gekauften Bosch Smart Home auch unsere Heizung und Lüftersteuerung per Handy von außerhalb steuern können. Leider ist das ja nicht der Fall.
Jetzt habe ich ein wenig eingelesen und habe auch diesen Beitrag gefunden.
Was brauchen wir alles?
HA Green und noch zigbee oder?
Ich bin leider ein absoluter Einsteiger
Freundliche Grüße
Zigbee brauchst du dazu nicht. Auch nicht zwingend Home Assistant. Du benötigst eine Modbus-fähige Smart Home Zentrale. HA bietet sich da an. Die Daten werden dann per Netzwerk (LAN) ausgetauscht.
Danke für die schnelle Antwort.
Aber am einfachsten wäre HA und dann das im Netzwerk integrieren. Und dort dann grob gesagt alles Reinbasteln und später über z.b Google Sprachassi oder App von unterwegs steuern.
Du findest im Bedienteil die Bus-Adresse, daraus kannst Du dann die Adressen ermitteln:
z.B. wäre die Adresse für die Feigabe der Zusatzheizung für die Bus ID 2, die 442: