| * Shelly Pro 3EM - Net Metering (Saldierung) & Home Assistant Auto-Discovery | |
| * Version: 1.1.8 | |
| * | |
| * DISCLAIMER: | |
| * Use this script entirely at your own risk! I assume absolutely no liability | |
| * for any direct, indirect, or consequential damages. This includes, but is | |
| * not limited to, damage to the Shelly device, any connected electrical | |
| * equipment, other devices in your network, data loss, or system malfunctions. | |
| * By using this script, you acknowledge that you alone are responsible for | |
| * your hardware and setup. | |
| * | |
| * CHANGELOG (v1.1.1 → v1.1.8): | |
| * - Corrected HA Discovery MQTT topic (removed duplicate device prefix) | |
| * - Added null/type-checks for MQTT config, em component and KVS values | |
| * - Fixed race condition: main loop waits until KVS counters are fully loaded | |
| * - Replaced fixed startup delay with MQTT.setConnectHandler() | |
| * - Counter topics are now published retained for reliable HA recovery | |
| * - Availability uses native Shelly LWT topic (<id>/online, true/false) | |
| * - HA Discovery payload switched to short keys to stay under 512-byte MQTT limit | |
| * - Removed unused helper functions and objects to reduce RAM usage | |
| */ | |
| let CONFIG = { | |
| updateInterval: 500, // Calculation cycle in ms | |
| enablePersistence: true, // true = Save counter states to flash memory | |
| saveInterval: 1800, // Save to KVS every 1800 cycles (~15 min.) | |
| mqttPrefix: "homeassistant" // Standard HA Discovery Prefix | |
| }; | |
| let VERSION = "1.1.8"; | |
| let SHELLY_ID = null; | |
| let energyReturnedWs = 0.0; | |
| let energyConsumedWs = 0.0; | |
| let energyReturnedKWh = 0.0; | |
| let energyConsumedKWh = 0.0; | |
| let saveCounter = 0; | |
| let lastPublishedConsumed = ""; | |
| let lastPublishedReturned = ""; | |
| let countersLoaded = false; | |
| // ───────────────────────────────────────────── | |
| // 1. Helper Functions | |
| // ───────────────────────────────────────────── | |
| function TryAnnounceAndPublish() { | |
| if (!SHELLY_ID || !MQTT.isConnected()) return; | |
| AnnounceHA(); | |
| if (countersLoaded) PublishCounters(true); | |
| } | |
| function PublishCounters(force) { | |
| if (!SHELLY_ID || !countersLoaded) return; | |
| let valC = energyConsumedKWh.toFixed(3); | |
| let valR = energyReturnedKWh.toFixed(3); | |
| if (!force && valC === lastPublishedConsumed && valR === lastPublishedReturned) return; | |
| let okC = MQTT.publish(SHELLY_ID + "/energy_counter/consumed", valC, 0, true); | |
| let okR = MQTT.publish(SHELLY_ID + "/energy_counter/returned", valR, 0, true); | |
| if (okC) lastPublishedConsumed = valC; | |
| if (okR) lastPublishedReturned = valR; | |
| } | |
| // ───────────────────────────────────────────── | |
| // 2. MQTT Event Handlers | |
| // ───────────────────────────────────────────── | |
| MQTT.setConnectHandler(function () { | |
| print("MQTT connected."); | |
| TryAnnounceAndPublish(); | |
| }); | |
| MQTT.setDisconnectHandler(function () { | |
| // Cannot publish here – connection is already gone. | |
| // HA uses native Shelly LWT on <topic_prefix>/online for offline detection. | |
| print("MQTT disconnected."); | |
| }); | |
| // ───────────────────────────────────────────── | |
| // 3. Get Device ID and Initialize | |
| // ───────────────────────────────────────────── | |
| Shelly.call("Mqtt.GetConfig", {}, function (res, err_code, err_msg) { | |
| if (!res) { | |
| print("ERROR: Mqtt.GetConfig returned null! Code: " + err_code + " | " + err_msg); | |
| return; | |
| } | |
| SHELLY_ID = res.topic_prefix ? res.topic_prefix : null; | |
| if (!SHELLY_ID) { | |
| print("ERROR: No MQTT topic_prefix set. Please check MQTT configuration."); | |
| return; | |
| } | |
| print("Shelly ID: " + SHELLY_ID + " | Script v" + VERSION); | |
| if (CONFIG.enablePersistence) { | |
| LoadCounters(); | |
| } else { | |
| countersLoaded = true; | |
| print("Persistence disabled. Counters start at 0."); | |
| } | |
| // Handles script restarts when MQTT is already connected | |
| TryAnnounceAndPublish(); | |
| }); | |
| // ───────────────────────────────────────────── | |
| // 4. Home Assistant Auto-Discovery | |
| // ───────────────────────────────────────────── | |
| function AnnounceHA() { | |
| if (!SHELLY_ID) return; | |
| let haTopic = CONFIG.mqttPrefix + "/sensor/" + SHELLY_ID; | |
| let avtyTopic = SHELLY_ID + "/online"; | |
| let dev = { | |
| "ids": [SHELLY_ID], | |
| "name": "Shelly Pro 3EM", | |
| "mf": "Shelly", | |
| "mdl": "Pro 3EM", | |
| "sw": "Saldierung v" + VERSION | |
| }; | |
| let okImport = MQTT.publish( | |
| haTopic + "-import/config", | |
| JSON.stringify({ | |
| "name": "Saldierend Import", | |
| "uniq_id": SHELLY_ID + "_sald_import", | |
| "stat_t": SHELLY_ID + "/energy_counter/consumed", | |
| "unit_of_meas": "kWh", | |
| "dev_cla": "energy", | |
| "stat_cla": "total_increasing", | |
| "avty_t": avtyTopic, | |
| "pl_avail": "true", | |
| "pl_not_avail": "false", | |
| "dev": dev | |
| }), | |
| 0, true | |
| ); | |
| let okExport = MQTT.publish( | |
| haTopic + "-export/config", | |
| JSON.stringify({ | |
| "name": "Saldierend Export", | |
| "uniq_id": SHELLY_ID + "_sald_export", | |
| "stat_t": SHELLY_ID + "/energy_counter/returned", | |
| "unit_of_meas": "kWh", | |
| "dev_cla": "energy", | |
| "stat_cla": "total_increasing", | |
| "avty_t": avtyTopic, | |
| "pl_avail": "true", | |
| "pl_not_avail": "false", | |
| "dev": dev | |
| }), | |
| 0, true | |
| ); | |
| if (okImport && okExport) { | |
| print("HA Auto-Discovery sent."); | |
| } else { | |
| print("WARNING: HA Discovery publish failed (MQTT not ready?)."); | |
| } | |
| } | |
| // ───────────────────────────────────────────── | |
| // 5. Load / Save Persistence (KVS) | |
| // ───────────────────────────────────────────── | |
| function LoadCounters() { | |
| let loadedCount = 0; | |
| function checkDone() { | |
| loadedCount++; | |
| if (loadedCount === 2) { | |
| countersLoaded = true; | |
| lastPublishedConsumed = ""; | |
| lastPublishedReturned = ""; | |
| print("Counters ready. Consumed: " + energyConsumedKWh + " kWh | Returned: " + energyReturnedKWh + " kWh"); | |
| if (MQTT.isConnected()) PublishCounters(true); | |
| } | |
| } | |
| Shelly.call("KVS.Get", { "key": "EnergyConsumedKWh" }, function (res, err_code) { | |
| if (res && res.value !== undefined && res.value !== null) { | |
| energyConsumedKWh = Number(res.value); | |
| if (isNaN(energyConsumedKWh)) energyConsumedKWh = 0.0; | |
| print("Loaded EnergyConsumedKWh: " + energyConsumedKWh); | |
| } else if (err_code !== 0) { | |
| print("INFO: EnergyConsumedKWh not in KVS yet (first run?)."); | |
| } | |
| checkDone(); | |
| }); | |
| Shelly.call("KVS.Get", { "key": "EnergyReturnedKWh" }, function (res, err_code) { | |
| if (res && res.value !== undefined && res.value !== null) { | |
| energyReturnedKWh = Number(res.value); | |
| if (isNaN(energyReturnedKWh)) energyReturnedKWh = 0.0; | |
| print("Loaded EnergyReturnedKWh: " + energyReturnedKWh); | |
| } else if (err_code !== 0) { | |
| print("INFO: EnergyReturnedKWh not in KVS yet (first run?)."); | |
| } | |
| checkDone(); | |
| }); | |
| } | |
| function SaveCounters() { | |
| Shelly.call("KVS.Set", { "key": "EnergyConsumedKWh", "value": energyConsumedKWh.toFixed(3) }); | |
| Shelly.call("KVS.Set", { "key": "EnergyReturnedKWh", "value": energyReturnedKWh.toFixed(3) }); | |
| print("Counters saved to KVS."); | |
| } | |
| // ───────────────────────────────────────────── | |
| // 6. Main Calculation Loop | |
| // ───────────────────────────────────────────── | |
| Timer.set(CONFIG.updateInterval, true, function () { | |
| if (!SHELLY_ID || !countersLoaded) return; | |
| let em = Shelly.getComponentStatus("em", 0); | |
| if (!em || typeof em.total_act_power !== "number") return; | |
| let power = em.total_act_power; | |
| let energyStep = power * (CONFIG.updateInterval / 1000.0); | |
| if (power >= 0) { | |
| energyConsumedWs += energyStep; | |
| } else { | |
| energyReturnedWs += Math.abs(energyStep); | |
| } | |
| if (energyConsumedWs >= 3600) { | |
| let chunkC = Math.floor(energyConsumedWs / 3600); | |
| energyConsumedKWh += chunkC / 1000.0; | |
| energyConsumedWs -= chunkC * 3600; | |
| } | |
| if (energyReturnedWs >= 3600) { | |
| let chunkR = Math.floor(energyReturnedWs / 3600); | |
| energyReturnedKWh += chunkR / 1000.0; | |
| energyReturnedWs -= chunkR * 3600; | |
| } | |
| PublishCounters(false); | |
| if (CONFIG.enablePersistence) { | |
| saveCounter++; | |
| if (saveCounter >= CONFIG.saveInterval) { | |
| saveCounter = 0; | |
| SaveCounters(); | |
| } | |
| } | |
| }); |